Most Popular Products
Digital Turbidity Meter 335 / 331 / 341
Digital Turbidity Meter 335 / 331 / 341 Specification
- Voltage
- 240 Volt (v)
- Weight
- 15-20 Kilograms (kg)
- Power
- 10 Watt (w)
- Material
- Plastic
- Dimension (L*W*H)
- 144.0 x 167.5 x 70 Millimeter (mm)
Digital Turbidity Meter 335 / 331 / 341 Trade Information
- Minimum Order Quantity
- 1 Piece
- Payment Terms
- Cash in Advance (CID)
- Supply Ability
- 15 Pieces Per Day
- Delivery Time
- 1 Week
- Main Export Market(s)
- Western Europe, Australia, Eastern Europe, Central America, Africa, Middle East, South America, Asia, North America
- Main Domestic Market
- All India
About Digital Turbidity Meter 335 / 331 / 341
Digital Turbidity Meter - 335, 331 & 341
FEATURES
- Reliable & Accurate Results
- Measurements upto 1000 NTU
- 3 1/2 Digit 7-Segment LED Display
- Sewage and Drinking Water Testing
Digital Turbidity/Nephelo Meter are ideal instruments for the measurement of suspensions. They consist of a light source focused on a test tube containing the sample solution under test. The light, reflected at a right angle to the focused light by the suspension in the solution, is detected by the photodiode detector, amplified and displayed on 3 1/2 digit seven segment LED display.
SPECIFICATIONS
| Model | 335 | 331 | 341 |
| Product | Digital Turbidity Meter | Digital Turbidity Meter | Digital Nephelometer |
| Range | 0 - 1000 NTU (in 4 Ranges) 0 - 2, 20, 200, 1000 NTU | 0 - 1000 NTU (in 2 Ranges) 0 - 200, 1000 NTU | 0 - 200 NTU (in 2 Ranges) 0 - 20, 200 NTU |
| Resolution | 0.01 NTU | 1 NTU | 0.01 NTU |
| Accuracy | + 3% FS, + 1Digit | + 3% FS, + 1Digit | + 2% FS, + 1Digit |
| Display | 3 1/2 Digit 7-Segment LED | ||
| Light Source | IR LED | ||
| Detector | Photodiode | ||
| Sample System | 60 x 25mm Clear Glass Test Tubes | ||
| Power | 230 V + 10% AC, 50 Hz | ||
| Dimensions | 245 x 260 x 125 mm (L x B x H) (Approx.) | ||
| Accessories | Test tube Set of 5, Operation Manual, Dust Cover | ||
Precise Turbidity Measurement
Designed for accuracy, the Digital Turbidity Meter series 335/331/341 ensures reliable turbidity readings for water quality control. These meters cater to diverse sectors such as environmental monitoring, wastewater treatment, and industrial laboratories, helping users maintain stringent quality standards.
Robust and User-Friendly Design
Constructed with high-quality plastic, these meters combine durability with lightweight construction. Their compact dimensions make them suitable for on-site and laboratory environments, while user-friendly interfaces simplify operation for both professionals and technical staff.
FAQs of Digital Turbidity Meter 335 / 331 / 341:
Q: How does the Digital Turbidity Meter 335/331/341 operate?
A: The Digital Turbidity Meter functions by emitting a light source through a water sample and measuring the scattered light to determine turbidity. Simply connect to a 240V power supply, insert the sample, and follow on-screen instructions for instant readings.Q: What are the typical applications for these turbidity meters?
A: These meters are commonly used in environmental monitoring, wastewater management, drinking water quality testing, and various industrial processes where accurate measurement of suspended particles is crucial.Q: Where can the Digital Turbidity Meter be installed or used?
A: Thanks to their compact size and lightweight construction, these meters can be utilized both in laboratory settings and on-site field locations. Their robust plastic housing ensures suitability for demanding environments.Q: What is the process for measuring turbidity with these meters?
A: To measure turbidity, prepare your water sample, power on the device, and place the sample in the designated cuvette holder. The device then automatically calculates and displays the turbidity level.Q: What are the main benefits of using this meter for water quality analysis?
A: The main benefits include rapid and dependable measurements, ease of operation, portability, and suitability for a wide range of water samples, making it an excellent choice for organizations focused on water safety and quality control.Q: When should calibration of the turbidity meter be performed?
A: Calibration should be performed regularly, typically before each testing session or as recommended in the user manual, to ensure the accuracy and reliability of measurements.Q: Who can benefit from using this turbidity meter?
A: Exporters, manufacturers, and suppliers, especially within India, as well as researchers and technicians in environmental, industrial, and municipal sectors, will find significant value in using these digital turbidity meters for routine monitoring and analysis.
Price 180000 INR/ Piece
- Minimum Order Quantity
- 1 Piece
- Supply Ability
- 15 Pieces Per Day
- Delivery Time
- 1 Week
- Main Domestic Market
- All India
- Main Export Market(s)
- Western Europe, Australia, Eastern Europe, Central America, Africa, Middle East, South America, Asia, North America
Tell us about your requirement
Price:
Quantity
Select Unit
- 50
- 100
- 200
- 250
- 500
- 1000+
Additional detail
Mobile number
Email
![]() |
ESICO INTERNATIONAL
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |
English
Spanish
French
German
Italian
Chinese (Simplified)
Japanese
Korean
Arabic
Portuguese